Category: Engineering

  • “Out of Town Assignment: Completing Tasks on a Tight Schedule”

    Just complete the assignment and give what it requires, it’s not hard work I’m just out of town and have no time, thanks.

  • Title: Autocad: A Comprehensive Overview of the Leading Software for Professionals of Record

    Please research and write a paper on the software called autocad. This paper can address its’ history, its’ present use by the Professionals of Record, its’ costs, its’ future possibilities, its advantages and its’ disadvantages.

  • Technical Report Writing: Kinematic Viscosity Test Method for Transparent and Opaque Liquids “Kinematic Viscosity Testing for Non-Business Use: A Step-by-Step Guide”

    Instructions:
    Technical Report Writing
    26 May 2024 Course Code CE6104
    Presentation Skills and Engineering Report Writing
    Name
    This cover sheet must be completed (section in red below) and attached to your
    assessment before submission in hard copy/soft copy.
    The time allowed for this assessment is XXX minutes/hours/days.
    This assessment carries XXX marks distributed to a total of XXX questions
    assessing CILO X and CILO X.
    The materials allowed for use in this assessment are XXX, XXX, and XXX.
    The use of generative AI tools is strictly prohibited.
    References consulted (if any) must be properly acknowledged and cited.
    The assessment has a total of XXX pages.
    Learner ID
    Learner
    Name
    Lecturer’s
    Name
    Date May 20th, 2024
    Submitted
    Abdulaziz Qussay Daghfag 202307105
    Fahad AttaAllah
    Mohammad Al-Yami
    Mohammad Al-Rashid
    2023307128
    2023307261
    202307347
    Wajid Khan
    By submitting this assessment for marking, I affirm that this assessment is my own work.
    Non-Business Use
    Do not write beyond this line. For assessor use only.
    Assessor’s Name
    Marking Date
    Comments:
    Marks
    Obtained
    Standard Test Method for
    Kinematic Viscosity of Transparent and Opaque Liquids
    (and Calculation of Dynamic Viscosity)
    Non-Business Use
    Table of Contents
    SCOPE
    Significance and Use 4
    PRINCIPLE 4
    Items 6
    RESPONSIBILITY 6
    Procedure 6
    Calculation 11
    Conclusion & Critique 12
    References 12
    Non-Business Use
    1. Scope
    1.1.
    2.
    This test method covers and specifies a procedure for the concurrent measurement of both
    the dynamic viscosity, and the density of liquid petroleum products and crude oils, both
    transparent and opaque using constant temperature bath CANNON CT-1000HT. (ASTM,
    2021)
    Significance and Use
    2.1 Many petroleum products, and some non-petroleum materials, are used as lubricants,
    and the correct operation of the equipment depends upon the appropriate viscosity of the
    liquid being used. In addition, the viscosity of many petroleum fuels is important for the
    estimation of optimum storage, handling, and operational conditions. Thus, the accurate
    determination of viscosity is essential to many product specifications.
    2.2 Tracking viscosity is important when it comes to understanding conditions deep
    underground. The viscosity of oil and gas can be highly variable, depending on environmental
    temperature and pressure, as well as the molecular makeup of the raw material. Pressure and
    temperature changes cause viscosity readings to fluctuate dramatically, and can be irreversible.
    These characteristics must be controlled precisely through the sample extraction, handling, and
    analysis for fluid integrity. The viscosity system must safely
    provide accurate, repeatable, and timely information while using as little sample as possible.
    3. Principle
    3.1. Kinematic viscosity is measured by noting the time it takes oil to travel through the orifice of
    a capillary under the force of gravity (Figure 1). The orifice of the kinematic viscometer tube
    produces a fixed resistance to flow Different sized capillaries are available to support fluids of
    varying viscosity.
    3.2. This measured time is then multiplied by a constant (associated to the particular tube) to
    calculate the kinematic viscosity (force of gravity). (ASTM, 2021)
    Non-Business Use
    Non-Business Use
    Figure 1. Capillary U-Tube Viscometer
    Items
     Constant Temperature Bath.
     U-Tube Viscometer
     Thermometer.
     Stopwatch.
     Sample.
     Cleaning solvents (Toluene, Acetone) in a squeezed bottle.
     A piece of rag.
     Personal Protective Equipment (PPE), lab coat, goggles, safety shoes.
    4. Responsibility
    4.1. Analysts are responsible to perform the test and follow the procedure to obtain quality results.
    5. Procedure
    5.1 Measurement
    5.1.1 Start up the bath for a couple of hours to let the temperature reaches the set point.
    5.1.2 While the bath is running, heat up the sample in the oven.
    5.1.3 Pick out the right tube, depending on the nature of the sample, and make sure it is
    thoroughly cleaned with Toluene followed by a drying solvent (acetone).
    Non-Business Use
    5.1.4 Transfer the sample into the tube till the first red line, and let it settle down for a few
    minutes to adapt with bath’s temperature (As shown in the image below).
    5.1.5 Using the thumb finger, press on the top part of the tube (big opening), till the
    sample move past the curved part of the tube.
    5.1.6 Once the sample reaches the first red line that is situated at the bottom side of the
    tube, hit the stopwatch until the sample reaches the second redline. Then, stop the
    stopwatch.
    Non-Business Use
    Start Line
    Finish Line
    5.1.7 Go to the table of “Manual Viscosity Tube Factors”, and select the size of the tube
    you have used during the analysis, you will find the “Tube Factor”, multiply it by the number of
    seconds you have obtained in the stopwatch to calculate the final result.
    Result (mm2/s) = Tube Factor (mm2/s2) × Time (s) (ASTM, 2021)
    5.1.8 Repeat all the steps above in order to obtain a second reading. Two determinations of the
    kinematic viscosity of the test material are required. Report the average of the two duplicated
    kinematic viscosity results to four significant figures, together with test temperature.
    Non-Business Use
    Non-Business Use
    Figure 2 (left). Temperature Probe Immersion in Constant Temperature Bath
    Figure 3(right). Constant Temperature Bath Model Name: Cannon CT-1000HT
    Non-Business Use
    Figure 4. Common glass capillary types of kinematic viscometer. Glass Capillary Types (1)
    Ostwald (2) Ubbelohde (3) Cannon-Fenske (4) Houillon (Modified Zeitfuchs crossarm)
    6. Calculation
    Five kinematic viscosity of Arabian extra light crude oil values were measured at 210°F by using
    calibrated viscometer tubes.
    Repeat Number
    1
    2
    3
    4
    5
    Duplicated runs (mm2/s)
    787
    785
    785
    783
    797
    795
    783
    779
    794
    795
    Average (mm2/s)
    786
    784
    796
    781
    794.5
    Based on this test
    6.017 and a repeatability of 6.6 mm2/s according to (ASTM D-445, Sec. 17).
    Determinability (d), were found to be 2.82, 2.82, 2.86, 2.81 & 2.86 mm2/s respectively to the
    duplicated analysis, which approve that our duplicated runs don’t exceed their indicated
    determinability limits according to (ASTM D-445, Sec. 17).
    By this validation, the method fits for purpose. (ASTM, 2021)
    Non-Business Use
    data the average is 787.2 mm2/s. This gives a sample standard deviation of
    Conclusion & Critique
    This test requires a great deal patience and precision. Yet, it provides extremely reliable results.
    Furthermore, the technician has to try several tubes that fit the type of sample especially if he
    received an unknown sample from a new field or well in which he has little to no idea about the
    site or sample specifications.
    This is not the case with modern instruments that came out recently in the markets in various
    shapes and sizes. Particularly, automated ones which is capable of producing multiple results in a
    swift manner (Time is a valuable resource in the petroleum industry). Most importantly, obtained
    figures are dependable and match the ones taken from the manual procedure.
    Automatic analyzers have a high price tag, mainly that come with extra features such as built-in-
    oven and auto sampling, only a handful of oil corporates could afford these machines.
    Another drawback worth noting before bringing this article to an end is that petroleum laboratories
    around the world run the risk of losing or breaking the viscometer tubes during cleaning or
    relocation, etc. Those tubes are made of glass, high-priced, and takes an extended amount of time
    to receive it from outside the kingdom. Worst of all, it contains a hazardous substance called
    Mercury which would cause multiple health issues such as poisoning and acute lung injury. It is
    highly recommended to switch to automated viscometer to promote safety across the lab area.
    References
    ASTM. (2021). Academia. Retrieved from Academia:
    https://www.academia.edu/36792221/Designation_D_44…
    Kinematic_Viscosity_of_Transparent_and_Opaque_Liquids_the_Calculation_of_Dynamic_
    Viscosity_1
    Non-Business Use

  • “Exploring the Use of Qualitative Research Design in Understanding Problem-Specific Requirements: A Research Presentation” I. Introduction A. Explanation of the research problem B. Importance of understanding problem-specific requirements C. Purpose of

    write research presentation with outline research problem introduction,research framework, understanding problem specific requirements,use of qualitative research design, research problem obejectives, summary

  • Title: Comparison of Self-Driving and Regular Vehicles: A Recommendation Report for Tesla’s Model Y and the 2024 Audi A6 Introduction: The automotive industry has been rapidly evolving in recent years, with advancements in technology leading to the development

    This is a recommendation report that is meant to compare Self-driving and regular vehicles, based certain criteria. Don’t just compare the 2 cars and say which vehicle is better. Provide data for the criteria provided and explain in detail how one car is better than the other for that criteria.
    The links will provide an outline for the report, what the professor is asking for, and a draft of my introduction section that you could revise or redo if you think it is necessary. 
    The criteria that should be discussed are convenience, fuel efficiency, and safety. Compare Tesla’s Model Y and the 2024 Audi A6.
    Provide all cited sources and use the ASME citing format when applicable.

  • “Molecular Dynamics Simulation of Interfacial Interactions and Competitive Adsorption of PNVCL and PAM on NaMMT Clay Surfaces at Different Temperatures”

    The study aims at using molecular dynamics simulation to broaden our knowledge of the
    interfacial interaction of PNVCL and PAM on the surface of NaMMT, investigate the
    adsorption similarities and differences of PNVCL and PAM on the surface of NaMMT at
    different temperatures, study the competitive adsorption relationship between PNVCL and PAM
    at different temperatures and reveals its adsorption law. Study the adsorption law of PNVCL
    with different adsorption groups on clay surfaces at different temperatures and reveal their
    key differences and connections with PAM. The simulations will be carried out using the large-scale atomic molecule massively
    parallel simulator (LAMMPS) developed by Sandia National Laboratories

  • “Final Exam Practice: Comprehensive Review with Detailed Solutions”

    Hello, I am preparing for a final exam. I have a past final exam but no solutions. I would like someone to do this past final exam with detailed solutions.

  • Title: A Systematic Review of Literature and Proposed Algorithm Framework for the Utilization of Artificial Intelligence and Machine Learning in Rotorcraft Path Planning

    Please perform a systematic review of literature in order to propose a algorithim framework for the utilization of artifical intelligence and machine learning in rotorcraft path planning. First review the problem description and powerpoint to get a sense of the project before beginning. Propose some type of solution to solve the problem. Please use the template to produce the same format, example to review format, outline for ideas and most importantly the rubric. Please propose complete up to literature review and a technical approach that uses the AFSIM environment and support chosen algorithims with mathematics whenever possible. Feel free to deviate from outline as needed. 

  • “Analyzing Customer Order Data: Identifying Key Questions for Effective Analysis”

    I have a dataset and I am trying to analyze it. I need someone who can understand the data and my thesis within the short period and identify questions that can help answer
    Important Info
    The order was placed through a short procedure (customer skipped some order details).
    Please clarify some paper details before starting to work on the order.
    Type of paper and subject
    Number of sources and formatting style
    Type of service (writing, rewriting, etc)

  • Title: The Impact of Social Media on Mental Health: A Literature Review

    Do a literature review an introduction and a one main point topic all 14 pages in total
    Important Info
    The order was placed through a short procedure (customer skipped some order details).
    Please clarify some paper details before starting to work on the order.
    Type of paper and subject
    Number of sources and formatting style
    Type of service (writing, rewriting, etc)